Items that ran out of attempts, and how to get them moving again.

An item that fails is retried with a widening backoff. After enough attempts it stops and becomes a dead letter, so that a permanent problem does not consume the queue for ever.

The Stopped work tab of Queue groups them by the reason they stopped. That grouping is the useful part: four hundred stopped items is usually one problem with four hundred instances.

CodeWhat it meansWhat fixes it
ErrorItemNotFoundThe card is not there any moreReconcile: it will be recreated
ErrorFolderNotFoundThe managed folder is goneReconcile: it rebinds or recreates
ErrorQuotaExceededThe recipient’s mailbox is fullTheir problem to fix; retry after
TransientFailureA temporary failure outlasted its attempts: a mailbox busy past the five-minute wait for a write slot, a timeout, a dropped connectionRetry once Microsoft 365 answers. A mailbox that stays busy has more writers than slots, or one stuck: check Queue’s Workers tab
DestinationDeletionGuardA bulk deletion is held for approvalApprove or reject it on the source

ErrorAccessDenied used to be the first row of that table, and it no longer belongs there. Exchange refusing a mailbox — the person is outside the RBAC for Applications scope or the Application Access Policy the application was granted — is met once and then held, not retried to exhaustion: the first refusal parks everything queued for that mailbox under the code MailboxOutOfScope, so one excluded person costs one refusal rather than one refusal and one dead letter per contact.

That covers both directions. Delivery to them is held, and so is the work that takes their data back out when they are removed — clearing withdrawn fields, deleting the managed folder. A removal that cannot run is held rather than failed, which is why it raises no failed subscription and no alert.

Where to look instead: Recipients filtered to Outside app scope, the bell and the Overview’s Attention, which list each refused recipient under Faults, and the PRTG channel Mailboxes outside the Exchange scope. The remedy is in Exchange, and the two ways out of a held removal are in What the faults mean.

A person with no mailbox at all is held the same way. Without an Exchange Online licence there is no mailbox, Graph answers 404 for it, and the folder reads No mailbox under the same code.

Nothing here needs retrying. The first request to the mailbox that Exchange answers releases what the refusal held, on every folder of the person. ContactMesh asks again every 15 minutes, and Check access again in the folder’s menu asks at once.

Checklist, in this order:

  1. The person has an Exchange Online licence and a mailbox. Without a licence there is no mailbox, Graph answers 404, and the folder reads No mailbox rather than out of scope.
  2. The person is a direct member of the mail-enabled security group the RBAC scope names. Membership through a nested group does not count; scripts/Add-ContactMeshGroupMember.ps1 adds a group’s users to it directly.
  3. Membership and RBAC changes take 30 minutes to 2 hours to reach Exchange.
  4. Check access again in the folder’s menu, or the tenant’s Setup check, confirms it.

Fix the cause first. Then retry that reason’s group, which puts those items back with a full set of attempts.

Retrying without fixing anything puts them back so they can fail again — and worse, it buries the groups that would have succeeded. That is why the button is offered per reason rather than as one button for everything.

TransientFailure is the group where retrying is the fix: a timeout, a dropped connection or a server error that gave no reason, tried until its attempts were spent. Retry it once Microsoft 365 answers again.

Retrying is the right answer when the cause has been fixed outside ContactMesh. It is the wrong answer when there is nothing outside ContactMesh to fix: a failure inside the product — the code InternalFailure — comes from an invariant that threw, and an invariant throws identically on the next attempt. The row says so.

Give up cancels that group. Use it when the work no longer makes sense to run: the contact it was for is gone, the folder has been reset, or the failure is ours and is being fixed in a release rather than by another attempt.

It is one way. A group that has been given up on is no longer stopped work, so the retry button will not bring it back; what the items would have written or removed stays as it is, and a reconciliation of the folder is what queues the work again if it turns out to be needed.

Both buttons are scoped to one reason, for the same argument: the code is the evidence that the decision applies.

Each group reads as a sentence, then the code and one example underneath it. The sentence is what to act on; the code is the half to paste into a ticket or a search, and it matters — ErrorAccessDenied and ErrorRecoverableItemsAccessDenied arrive as the same refusal from Microsoft and mean two entirely different fixes.

Three sentences are about the code itself rather than the failure. Not a code this version has a sentence for means the code came from Microsoft or from a newer ContactMesh than the dashboard; the example beside it is the detail as reported. This fault was stored without the figures its sentence needs means the code is one this version knows, recorded before its figures were kept with it. This stopped without recording a reason means the failure path did not classify itself, which is ours — the service log has the rest.